Line 45: Line 45:
  
  
-<code> 
-Command Details of SubUnit: MAIN 
-AVAIL 
  
 +Command Details of SubUnit: MAIN
 PWR PWR
 [PUT Command] [PUT Command]
-@MAIN:PWR=+**@MAIN:PWR=**
 [Parameters] [Parameters]
-Standby+**Standby**
 PUT: turining its state to Standby / GET: indicating Standby status. PUT: turining its state to Standby / GET: indicating Standby status.
-On+**On**
 PUT: turining its state to On / GET: indicating On status. PUT: turining its state to On / GET: indicating On status.
-On/Standby+**On/Standby**
 PUT Only: toggling its status between On/Standby PUT Only: toggling its status between On/Standby
  
 SLEEP SLEEP
 [PUT Command] [PUT Command]
-@MAIN:SLEEP=+**@MAIN:SLEEP=**
 [Parameters] [Parameters]
-Off+**Off**
 PUT: turining its setting state to Off / GET: indicating Off setting status. PUT: turining its setting state to Off / GET: indicating Off setting status.
-30 min+**30 min**
 PUT: setting to 30 min / GET: indicating it's setting is 30 min. PUT: setting to 30 min / GET: indicating it's setting is 30 min.
-60 min+**60 min**
 PUT: setting to 60 min / GET: indicating it's setting is 60 min. PUT: setting to 60 min / GET: indicating it's setting is 60 min.
-90 min+**90 min**
 PUT: setting to 90 min / GET: indicating it's setting is 90 min. PUT: setting to 90 min / GET: indicating it's setting is 90 min.
-120 min+**120 min**
 PUT: setting to 120 min / GET: indicating it's setting is 120 min. PUT: setting to 120 min / GET: indicating it's setting is 120 min.
-Last+**Last**
 PUT Only: setting to the value set last PUT Only: setting to the value set last
  
-VOL+**VOL**
 [PUT Command] [PUT Command]
-@MAIN:VOL=+**@MAIN:VOL=**
 [Parameters] [Parameters]
-Down+**Down**
 PUT Only: decrementing by 1 step (0.5dB) PUT Only: decrementing by 1 step (0.5dB)
-Up+**Up**
 PUT Only: incrementing by 1 step (0.5dB) PUT Only: incrementing by 1 step (0.5dB)
-Down 1 dB+**Down 1 dB**
 PUT Only: decrementing by 1 dB PUT Only: decrementing by 1 dB
 Up 1 dB Up 1 dB
Line 102: Line 100:
 The unit for this parameter is "dB". The unit for this parameter is "dB".
  
-MUTE+**MUTE**
 [PUT Command] [PUT Command]
-@MAIN:MUTE=+**@MAIN:MUTE=**
 [Parameters] [Parameters]
-Off+**Off****Bold Text**
 PUT: turining its state to Off / GET: indicating Off status. PUT: turining its state to Off / GET: indicating Off status.
-Att -40 dB+**Att -40 dB**
 PUT: attenuating by 40 dB from current volume status. / GET: indicating attenuated by 40 dB from current PUT: attenuating by 40 dB from current volume status. / GET: indicating attenuated by 40 dB from current
 volume status. volume status.
Line 512: Line 510:
 PUT Only: change its state to Stop PUT Only: change its state to Stop
 Pause Pause